[ RadSafe ] Measuring alphas with GM? Re: Survey MDAs vs. Scan MDAs
Emil
kerrembaev at yahoo.com
Wed May 10 16:03:26 CDT 2006
Ron,
Is it a joke?
Not to offend anybody but I am wondering how do you measure alphas
with GM detector???
The GM window thickness makes it impossible.
Regards,
Emil.
@radlab.nl>
Cc: 'John Andrews' <jandrews at whoi.edu>, 'steven pike'
<spike at whoi.edu>, 'Mary McGeoghegan' <Dear Radsafe list:
I'm trying to determine the Minimum Detectable Activity (MDA) for
gross
alpha measurements using a GM detector coupled to a rate meter. Some
colleagues have pointed me to NUREG-1757, which I have reviewed.
NUREG-1757
refers to NUREG-1507, "Minimum Detectable Concentrations with Typical
Radiation Survey Instruments for Various Contaminants and Field
Conditions",
June 1998. However, I cannot locate this document on NRC's web site.
Apparently, they do not keep 'older' documents on their web site.
Does
anyone have the proper MDA equations for evaluating (a priori) the
sensitivity of a rate meter? It is my understanding that the
standard MDA
equation for integrated measurements (scaler mode) does not apply to
rate
meters. A link to NUREG-1507 would also be appreciated.
Please reply directly to me. Thank you.
-----
Ron Reif, P.E.,CHP,CIH
EH&S Manager
Woods Hole Oceanographic Institution
http://ehs.whoi.edu
p:508-289-3788
f:508-457-2015
__________________________________________________