[ RadSafe ] NPL Environmental Radioactivity Proficiency Test Exercise 2007
Arvic Harms
Arvic.Harms at npl.co.uk
Tue Nov 14 11:21:53 CST 2006
Dear Sir or Madam,
I am pleased to inform you that the 2007 NPL Environmental Radioactivity Proficiency Test Exercise will begin shortly.
The provisional timetable for the exercise is as follows:
Samples ready for despatch March 2007
Deadline for submission of results 16 June 2007
The cost of participation in this exercise is £135 (excluding despatch) per sample.
Types of samples available:
Alpha High (AH): 20 g aqueous sample, nuclides 1-20 Bq/g; Ra-226, Np-237, U-238, Pu-238, Pu-239, Am-241
and Cm-244
Alpha Low (AL): 500 g aqueous sample, nuclides 1-20 Bq/kg; same nuclide composition as sample type AH
Beta 1 High (BH): 100 g aqueous sample, nuclides 1-20 Bq/g; H-3, Fe-55, Ni-63, Sr-89, Sr-90 and Tc-99
Beta 1 Low (BL): 500 g aqueous sample, nuclides 1-20 Bq/kg; same nuclide composition as sample type BH
Beta 2 (B2): 500 g aqueous sample, nuclides 0.1-0.5 Bq/g; H-3 (aqueous and OBT), C-14 (carbonate),
I-129 and Cl-36
Concrete (C): crushed concrete sample (50 g) containing a variety of radionuclides including: H-3, C-14,
Ca-41, Fe-55, Co-60, Ni-63, Ba-133, Eu-152 and Eu-154
Gamma High (GH): 100 g aqueous sample, nuclides 1-20 Bq/g. Mixture of at least eight gamma-emitting
radionuclides from the candidate list below
Gamma Low (GL): 500 g aqueous sample, nuclides 1-20 Bq/kg. Mixture of at least eight gamma-emitting
radionuclides from the candidate list below
Be-7, Na-22, K-40, Sc-46, Cr-51, Mn-54, Fe-59, Co-56, Co-57, Co-58, Co-60, Zn-65, Sr-85, Y-88, Y-91, Zr-95, Nb-95, Ru-103, Ru-106, Cd-109, Ag-110m, Ag-111, Sn-113, Te-123m, Sb-124, Sb-125, I-125, Cs-134, Cs-137, Ba-133, Ba-140, Ce-139, Ce-141, Ce-144, Nd-147, Eu-152, Eu-154, Eu-155, Gd-153, Tb-160, Ho-166m, Tm-170, Ir-192, Hg-203 and Bi-207
If you are interested in participating please contact me at arvic.harms at npl.co.uk
The Report from the 2005 Exercise is available at http://www.npl.co.uk/ionrad/publications/
Best regards,
Arvic Harms
Dr Arvic Harms
National Physical Laboratory
Hampton Road
Teddington TW11 0LW
Middlesex
United Kingdom
E-mail: arvic.harms at npl.co.uk
-------------------------------------------------------------------
This e-mail and any attachments may contain confidential and/or
privileged material; it is for the intended addressee(s) only.
If you are not a named addressee, you must not use, retain or
disclose such information.
NPL Management Ltd cannot guarantee that the e-mail or any
attachments are free from viruses.
NPL Management Ltd. Registered in England and Wales. No: 2937881
Registered Office: Serco House, 16 Bartley Wood Business Park,
Hook, Hampshire, United Kingdom RG27 9UY
-------------------------------------------------------------------
More information about the RadSafe