[ RadSafe ] Oncology 'laser'

John R Johnson idias at interchange.ubc.ca
Thu Nov 23 08:50:03 CST 2006


Floyd

Some clarification is required. The amount of Rn-222 given off depends on
the amount of Ra-226 present and the amount of Rn-222 that builds up in the
chamber reaches a maximum that is governed by its ~3.8 day halflife.

John
 _________________
John R Johnson, Ph.D.
*****
President, IDIAS, Inc
4535 West 9-Th Ave
Vancouver B. C.
V6R 2E2
(604) 222-9840
idias at interchange.ubc.ca
*****

-----Original Message-----
From: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl]On
Behalf Of Flanigan, Floyd
Sent: November 22, 2006 10:06 PM
To: edmond0033; radsafe at radlab.nl
Subject: RE: [ RadSafe ] Oncology 'laser'


Radium 226 gives off Radon at a constant of .0001ml/day. This would be
in a sealed chamber with a mirrored interior surface and a fiber-optic
cable affixed to the only opening. The entire chamber would be cooled to
-195C and the Radon 222 emitted from the Radium 226 in the chamber would
be the source. The longer the Radium remained sealed in the chamber, the
more Radon would build up in the chamber, and, theoretically, the
stronger the source light would become. There would have to be a
throttle of sorts, controlling aperture size on the laser pen to control
the beam.

Floyd W. Flanigan B.S.Nuc.H.P.


-----Original Message-----
From: edmond0033 [mailto:edmond0033 at comcast.net]
Sent: Wednesday, November 22, 2006 12:18 PM
To: Flanigan, Floyd; radsafe at radlab.nl
Subject: Re: [ RadSafe ] Oncology 'laser'

Do you mean Radium-226 or Radon-222?

Ed Baratta
edmond0033 at comcast.net
----- Original Message -----
From: "Flanigan, Floyd" <Floyd.Flanigan at nmcco.com>
To: <radsafe at radlab.nl>
Sent: Wednesday, November 22, 2006 6:20 AM
Subject: [ RadSafe ] Oncology 'laser'


Okay ... Here's the rub:



When Radon 226 is cooled to -195C, it gives off an orange-red light. If
said light was captured and channeled through a fiber-optic cable to a
light pen, and one incised a patient to expose a cancerous tumor, could
one affect said tumor with a Beta burn with the emissions from the light
'laser' pen? And if so, would this be an effective means of eradicating
said tumor?



How's that for a 'what if' ?



Floyd W. Flanigan B.S.Nuc.H.P.

_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood
the
RadSafe rules. These can be found at:
http://radlab.nl/radsafe/radsaferules.html

For information on how to subscribe or unsubscribe and other settings
visit:
http://radlab.nl/radsafe/


_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at:
http://radlab.nl/radsafe/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit:
http://radlab.nl/radsafe/




More information about the RadSafe mailing list