[ RadSafe ] FW: RADOS Rad 51 angular response

Sandy Perle sandyfl at cox.net
Tue Apr 10 09:12:05 CDT 2007


A question was recently posted on Radsafe requesting information on IEC
61283 angular response of the Rados 51. Since the information was provided
by Rados and they are currently not members of the Radsafe listserver, I am
posting their response and data. I am also copying Powernet since there are
those who also use the Rados 51 who are members of Powernet.

Regards,

Sandy

----------------------------------------------------------------
Sandy Perle 
Senior Vice President, Technical Operations 
Global Dosimetry Solutions, Inc. 
2652 McGaw Avenue
Irvine, CA 92614
 
Tel: (949) 296-2306 / (888) 437-1714 Extension 2306 
Tel: (949) 419-1000 Extension 2306
Fax:(949) 296-1144
 
Global Dosimetry Website: http://www.dosimetry.com/ 
Personal Website: http://sandy-travels.com/ 
 

-----Original Message-----
From: Johanna.Makela at rados.fi [mailto:Johanna.Makela at rados.fi] 
Sent: Tuesday, April 10, 2007 2:38 AM
To: 'Johansen, Kjell'; radsafe at radlab.nl
Cc: Sandy Perle; Jim Kost; tsalomaa at rados.fi
Subject: RE: RADOS Rad 51 angular response


Dear Kjell,

The IEC 61283 requirements for angular response (page 31, chapter 8.5
"Variation of Response with Angle of Incidence of Radiation") are attached.
Second attachment is a paragraph from the type test report of RAD-51,
showing that RAD-51 complies to the requirements set in the mentioned
standard.

Should you have further questions, please feel free to contact us any time.

Best regards,

Johanna Mäkelä

Rados Technology Oy
synOdys Group
P.O.Box 506, 20101 Turku, Finland
tel. +358-2-4684 661
fax +358-2-4684 601
e-mail johanna.makela at rados.fi
http://www.rados.com

(See attached file: IEC61283_p31.pdf)

(See attached file: Angular_response_RAD51.JPG)

Johanna Mäkelä

Rados Technology Oy
synOdys Group
P.O.Box 506, 20101 Turku, Finland
tel. +358-2-4684 661
fax +358-2-4684 601
e-mail johanna.makela at rados.fi
http://www.rados.com


Kjell,

Rados is a SynOdys Company, and is a sister company of GDS (we're all part
of Mirion Technologies, Inc.)

Here is Rados's mailing address ad phone information. I am also copying Ms.
Johanna Makela and Mr. Timo Salomaa, both with Rados as well as Jim Kost
from MGP. They can assure you that you receive the information that you
need.

Turku
Rados Technology Oy
P.O. Box 506
FIN-20101 Turku
Finland
Phone: +358 2 4684 600
Fax: +358 2 4684 601
http://www.rados.com

Regards,

Sandy

----------------------------------------------------------------
Sandy Perle
Senior Vice President, Technical Operations
Global Dosimetry Solutions, Inc.
2652 McGaw Avenue
Irvine, CA 92614

Tel: (949) 296-2306 / (888) 437-1714 Extension 2306
Tel: (949) 419-1000 Extension 2306
Fax:(949) 296-1144

Global Dosimetry Website: http://www.dosimetry.com/
Personal Website: http://sandy-travels.com/




-----Original Message-----
From: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl] On
Behalf
Of Johansen, Kjell
Sent: Thursday, April 05, 2007 1:37 PM
To: radsafe at radlab.nl
Subject: [ RadSafe ] RADOS Rad 51 angular response

I need to find out what European Union standards document IEC 61283 has
to say about the angular response of electronic dosimeters.  Currently,
we have the RADOS model RAD 51 electronic dosimeters and the literature
that came with them states that the dosimeter conforms to the
aforementioned standard with respect to angular response.  RADOS was
bought out so we can not contact them for this information.  Help would
be appreciated.



Kjell Johansen

Point Beach Nuclear Plant

Two Rivers, WI 54241

kjell.johansen at nmcco.com




-------------- next part --------------
A non-text attachment was scrubbed...
Name: IEC61283_p31.pdf
Type: application/pdf
Size: 124764 bytes
Desc: not available
URL: <http://health.phys.iit.edu/pipermail/radsafe/attachments/20070410/05df3d07/attachment-0001.pdf>


More information about the RadSafe mailing list