[ RadSafe ] Beta Correction Factor

Redmond, Randy (RXQ) redmondrr at y12.doe.gov
Thu Dec 6 11:01:32 CST 2007


We do our beta correction factors at contact with U-238 and they are
typically 3.2 to 3.8.  Sr/Y-90 is done at ORNL at 30cm and is typically
1.1 to 1.3. 

Randy Redmond
BWXT Y-12
Radiological Engineering
865-574-5640



-----Original Message-----
From: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl] On
Behalf Of Dave Biela
Sent: Wednesday, December 05, 2007 1:47 PM
To: radsafe at radlab.nl
Subject: [ RadSafe ] Beta Correction Factor

Looking for technical data on the Beta Correction Factor for:

1.  R.O. 20
2.  Contact Window Open
3.  Sr/Y-90

I have data for 30cm but could not find it for a contact reading.

Thanks
Dave
_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood
the RadSafe rules. These can be found at:
http://radlab.nl/radsafe/radsaferules.html

For information on how to subscribe or unsubscribe and other settings
visit: http://radlab.nl/radsafe/



More information about the RadSafe mailing list