Dustin:

>NO, Henry, you are not correct....

To reply in-kind...

YES, Dustin, I know I am not correct: now!  The same goes to Jeff, Bill, 
and everyone else who was kind enough to respond to my posts on this 
subject.

I stand corrected with respect to the individual sources' activity 
concentrations AND activity limits for exempt consignment not meeting the 
definition of Radioactive Material per 49CFR and possibly IATA , IMDG, and 
other regulations (i.e USPS) and tariffs (i.e. DHL, FedEx, UPS, etc.).

As the sources as described and will be offered for shipment/transport do 
not meet the definition of radioactive material and is therefore not 
subject to the US HMR, I concede that the sources do not have to be 
classified Class 7 Radioactive material or marked as either UN2910 or 
UN2911 for transportation in the US.  As I do not have the IATA/IMDG 
regulations in my office at this time (there are several on-site), I am 
not able to confirm that this is the case for international shipment / 
transport.

Also, I appreciate your suggestions in your subsequent post regarding DOT 
training.  However, it is not possible for a trainer to train one on every 
detail of the DOT, IATA, IMDG, and all other regulations.  There comes a 
point where after training, the trainee must carefully and thoroughly 
review the dangerous goods / hazardous materials transportation 
requirements themselves to insure that the packages and consignments he 
offers for shipment / transportation meet all of the applicable 
requirements prior to offering the packages and consignments.  This 
particular discussion and case has alerted me that I need to reset my 
thoroughness and care when preparing or offering radioactive packages for 
shipment / transportation or when offering guidance to others.

Thank you all for the discussion!

Henry

Boyd H. Rose, CM, CIH, CHMM
Sr. Safety and Environmental Engineering Specialist
Corporate Radiation Safety Officer
General Dynamics Land Systems
38500 Mound Road
Mail Zone 436-10-75
Sterling Heights , MI 48310-3269
Tel: 586 825 4503
Fax: 586 825 4015
E-mail: roseb at gdls.com





This is an e-mail from General Dynamics Land Systems. It is for the intended recipient only and may contain confidential and privileged information.  No one else may read, print, store, copy, forward or act in reliance on it or its attachments.  If you are not the intended recipient, please return this message to the sender and delete the message and any attachments from your computer. Your cooperation is appreciated.




More information about the RadSafe mailing list