[ RadSafe ] low energy gamma-spikes
Alston, Chris
ALSTONCJ at gunet.georgetown.edu
Tue Sep 28 12:51:07 CDT 2010
Marco
Yes, the doserate would have to be very high for an E-compensated GM detector to see something at 25 keV. Noise from the high tension power lines would be my first guess, too.
Cheers
cja
-----Original Message-----
From: marco bähler [mailto:m.c.baehler at bluewin.ch]
Sent: Monday, September 27, 2010 2:51 PM
To: radsafe at health.phys.iit.edu
Subject: [ RadSafe ] low energy gamma-spikes
dear group
I live close to an old bwr and went for a walk with my BNC 935 / 3inch NaI. it was towards the end of the annual refueling period.
500m downwind, calm wind, on the open field suddenly I recorded several short alarms, lasting between one and 12 seconds. countrates up to 15000cps. energy almost exclusively around 25 keV. I am wondering what this could have been.
answers from the authorities range from "noise due to high tension lines" (actually 200m away) to "probably x-ray exams somewhere" and "no hear no see no say" or "cosmic particle showers".
one answer referred to the gm-tube-equipped doserate-monitoring network which "recorded nothing". I think it is quite common for compensated gm tubes not to see 25 keV.
Is someone of YOU familiar with such spikes (me thinks I can call them clouds) and knows possible sources/causes? (Cd109??)
kind regards and thankyou for pondering
marco bähler
(euratom level 5b, 2004 utrecht)
uetikon
switzerland
CONFIDENTIAL: The information contained in this communication,
including its attachments may contain confidential information and
is intended only for the individual (s) or entity (ies) to whom it
is addressed . The information contained in this communication may
also be protected by legal privilege , federal law or other
applicable law. If you are not the intended recipient of this
communication , you are hereby notified that any distribution,
dissemination or duplication of this communication is strictly
prohibited. If you have received this communication in error please
immediately delete and destroy all copies of this message and
please immediately notify us of the error by separate communication
. Thank you.
More information about the RadSafe
mailing list