EPA-520 "Limiting Values ... and DCF ..." lists 4.29 E 2 rem/Ci for the
whole body Committed Effective Dose Equivalent after unit conversions. 
However, 7.81 E 3 rem/Ci is listed as the limiting DCF for Bone
Surfaces.

Hope this might help.

Glenn Roberts


"Hooda, Benny" wrote:
> 
> Radsafers:
> Does any one have an opinion regarding use of  Committed Effective Dose
> Equivalent conversion factor for Pu-239 (class W, inhalation) from FGR 11
> and Radiological Health Handbook or from DOE/EH-0071. The values listed are
> different 4.29E 2 rem/curie for FGR 11 and 5.10 E 2 rem/curie for
> DOE/EH-0071.
> Thanks,
> 
> -/-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/
> Benny Hooda,
> Senior Scientist
> Westinghouse Electric Corporation
> WIPP
> P.O.Box 2078 M/S 910-20
> Carlsbad, NM 88221
> (505)234-8932 Voice
> (505)885-0974 Fax
> Hoodab@WIPP.Carlsbad.NM.US
> Hoodab@caverns.com
> /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/ /-/
> ************************************************************************
> The RADSAFE Frequently Asked Questions list, archives and subscription
> information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html