[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Information
Dear colleagues I need to prepare an information, please, who can confirm
the below data:
Approximate dose rate to the hand for I Curie of Cs-137 (see note 1):
Surface Dose Rate 513 R/min, Dose Rate at 1 cm tissue depth 28 R/min, Dose
Rate at 3 cm tissue depth 3.7 R/min. For the purpose of calculations the
activity is considered to be a point source and Industrial source housing
are usually for stainless steel, outside diameter ¼ inch, with a wall of
1/32 inch thick, source considered point source.
(1) Ref. Training Course on Medical Planning and Care in Radiation
Accidents, Reference Manual REAC/TC, December 7/8, 1987, Rio de Janeiro,
Brazil.
Thanks for the help
Jose Julio Rozental
joseroze@netvision.net.il
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html