[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Cs-137/Ba-137 generators
Date: Wed, 14 Nov 2001 14:09:58 -0600
From: "Perrero, Daren" <Perrero@IDNS.STATE.IL.US>
Subject: RE: Cs-137/Ba-137 generators
The rest of the regulation in 10 CFR 30 indicates that no person may
manufacture or distribute such exempt quantities unless specifically
authorized by the the US NRC. So in this case all the burden of
responsibility legally rests with the initial distributor of the device or
quantities. The authorization granted by the US NRC for distribution may
hinge on the training/design of the product as well as the quantity.
The thoughts expressed are mine, mine, all mine!
I'm with the government, I'm here to help........
Daren Perrero, Health Physicist
perrero@idns.state.il.us
- -----Original Message-----
From: Tom Morgan [mailto:tmorgan@ISOTOPEPRODUCTS.COM]
Sent: Wednesday, November 14, 2001 1:34 PM
To: RadSafe (radsafe@list.vanderbilt.edu)
Subject: Cs-137/Ba-137 generators
Exempt quantities are governed by 10CFR30.18:
(a) Except as provided in paragraphs (c) and (d) of this section, any
person is exempt from the requirements for a license set forth in section 81
of the Act and from the regulations in parts 30 through 34, 36 and 39 of
this chapter to the extent that such person receives, possesses, uses,
transfers, owns, or acquires byproduct material in individual quantities
each of which does not exceed the applicable quantity set forth in §30.71,
Schedule B.
Exempt concentrations are governed by 10CFR30.14:
a) Except as provided in paragraphs (c) and (d) of this section, any person
is exempt from the requirements for a license set forth in section 81 of the
Act and from the regulations in this part and parts 31 through 36 and 39 of
this chapter to the extent that such person receives, possesses, uses,
transfers, owns or acquires products or materials containing byproduct
material in concentrations not in excess of those listed in §30.70.
Thomas L. Morgan, PhD
Director, Health Physics
Radiation Safety Officer
Isotope Products Laboratories
661-309-1033 (voice)
661-257-8303 (fax)
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.