[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
re[2]: shielding for Sr90 sealed source
Consider using MCNP.
Regards,
Harry
Harry J. Newman, CHP
NEXTEP Environmental, Inc.
808 Lyndon Lane, Suite 201
Louisville, KY 40222
502-339-9767 office
502-339-9275 fax
hnewman@nextep.cc
>> I'm mulling over the design of a
>> holder for a sealed Sr-90 2 mCi
>> source.
>> This beta emitter ( about .5 Mev)
>> decays to Y-90 (2.3 Mev) and
>> creates
>> some significant , energetic
>> Bremmstrahlung whenever it
>> impacts higher
>> atomic # materials, for instance
>> the end of the detector I'm
>> irradiating.
>> The source vendor has advised me
>> to shield the betas wherever
>> possible,
>> with 10-20 cm of acrylic, but I'm
>> troubled by the rather energetic >> scatter- whose energy will be a
>> continuum from approximately 2.3
>> Mev and
>> down.... Our calculations say
>> that about 2" of lead will bring
>> this
>> down to a couple of mR/hr, but
>> I thought perhaps someone has
>> had some
>> previous experience with this
>> situation. I already have
>> enough doorstops
>> and paperweights to remind me of
>> the perils of "rushing to
>> production"!
>> thanks in advance,
>> Bob Westerdale
>>
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.
You can view the Radsafe archives at http://www.vanderbilt.edu/radsafe/