     NRC's 9/5/95 Daily Event Report (DER) included the following DERs:

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29265         |
|FACILITY: COOK                     REGION:  3 |LAST UPDATE DATE:  09/02/95  |
+----------------------------------------------------------------------------+
| IMPROPER INSTALLATION OF THE SEAL ASSEMBLIES ON ELECTRICAL CONNECTIONS TO  |
| TWO REACTOR VESSEL HEAD VENT SOLENOID VALVES.                              |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29268         |
|FACILITY: OCONEE                   REGION:  2 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| TECHNICAL SPECIFICATION REQUIRED SHUTDOWN BECAUSE A 72-HOUR LIMITING       |
| CONDITION FOR OPERATION FOR AN INOPERABLE BACKUP POWER SUPPLY WAS EXCEEDED.|
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29269         +
|FACILITY: NINE MILE POINT          REGION:  1 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| THE PLANT HAD A MANUAL REACTOR SCRAM FROM 26% POWER.                       |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29270         +
|FACILITY: ZION                     REGION:  3 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| UNIT 1 ENTERED TECHNICAL SPECIFICATION 3.0.3 DUE TO LOW AIR PRESSURE ON    |
| ZONE 4 ISOLATION VALVE SEAL WATER TANK.                                    |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29271         |
|FACILITY: PERRY                    REGION:  3 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| UNPLANNED REACTOR CORE ISOLATION COOLING (RCIC) INITIATION SIGNAL DURING   |
| RESTORATION OF DIVISION 2 POWER SUPPLY.                                    |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29272         |
|FACILITY: INDIAN POINT             REGION:  1 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| UNIT SHUTDOWN AS A RESULT OF A LOSS OF THE CAPABILITY TO INITIATE A        |
| FEEDWATER ISOLATION SIGNAL FROM A REACTOR TRIP WITH A LOW REACTOR COOLANT  |
| SYSTEM TEMPERATURE CONDITION DUE TO A FAILED RELAY                         |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29273         |
|FACILITY: HARRIS                   REGION:  2 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| UNPLANNED AUXILIARY FEEDWATER ACTUATION DURING TESTING DUE TO A PROCEDURAL |
| PROBLEM                                                                    |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29274         |
|FACILITY: ARKANSAS NUCLEAR         REGION:  4 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| REACTOR TRIP ON HIGH STEAM GENERATOR LEVEL DUE TO THE INCREASE IN FEEDWATER|
| PUMP SPEED WHEN A PAINTER INADVERTENTLY VENTED THE 'B' MAIN FEEDWATER      |
| HEADER FLOW TRANSMITTER                                                    |
+============================================================================+

+============================================================================+
|FUEL CYCLE FACILITY                           |EVENT NUMBER:  29275         |
|FACILITY: BABCOCK & WILCOX CO.                |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| THE AMOUNT OF URANIUM-235 STORED IN A UNIT OF A STORAGE RACK ASSOCIATED    |
| WITH THE SCRAP MATERIAL RECOVERY OPERATION AT B&W NAVAL NUCLEAR FUEL       |
| FABRICATION FACILITY IN LYNCHBURG, VIRGINIA, EXCEEDED THE ADMINISTRATIVE   |
| LIMIT OF 350 GRAMS AS STIPULATED IN GENERIC LETTER 91-01.                  |
+============================================================================+

+============================================================================+
| GENERAL INFORMATION or OTHER                 |EVENT NUMBER:  29276         |
| CITY: ST. PETERSBURG         REGION: 2       |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| RESOURCE RECYCLING (A SCRAP METAL PROCESSING BUSINESS) OF ST. PETERSBURG,  |
| FLORIDA, IDENTIFIED AND CONTAINED A RADIOACTIVE SOURCE IN EXCESS OF FIVE   |
| MICRO-ROENTGENS PER HOUR ON CONTACT                                        |
+============================================================================+

+============================================================================+
|OTHER NUCLEAR MATERIAL                        |EVENT NUMBER:  29277         |
|LICENSEE: NORTH STAR STEEL COMPANY            |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| NORTH STAR STEEL COMPANY OF YOUNGSTOWN, OHIO, ACCIDENTALLY POURED LIQUID   |
| STEEL OVER THE TOP OF A 1,000 MILLICURIE CESIUM-137 SOURCE                 |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29278         |
|FACILITY: BRAIDWOOD                REGION:  3 |LAST UPDATE DATE:   09/01/95  
+----------------------------------------------------------------------------+
| POTENTIAL DEGRADED CONDITION FOR THE SAFETY INJECTION SYSTEM DUE TO        |
| CONFLICTING OPERABILITY DETERMINATIONS                                     |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29279         |
|FACILITY: SALEM                    REGION:  1 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO THE TRANSPORT OF A POTENTIALLY CONTAMINATED  |
| INDIVIDUAL OFFSITE TO AN OFFSITE MEDICAL FACILITY                          |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29280         |
|FACILITY: BROWNS FERRY             REGION:  2 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| INADVERTENT AUTOMATIC START OF ALL UNIT 3 EMERGENCY DIESEL GENERATORS WHILE|
| BOOTING A RELAY CONTACT DURING SCHEDULED SURVEILLANCE TESTING              |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29281         |
|FACILITY: ARKANSAS NUCLEAR         REGION:  4 |LAST UPDATE DATE:  09/01/95  |
+----------------------------------------------------------------------------+
| OFFSITE NOTIFICATIONS OF POTENTIAL FUEL OIL IN THE DISCHARGE CANAL.  (REFER|
| TO EVENT NUMBER 29285.)                                                    |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29282         |
|FACILITY: LIMERICK                 REGION:  1 |LAST UPDATE DATE:  09/02/95  |
+----------------------------------------------------------------------------+
| UNIT COMMENCED SHUTDOWN IN ACCORDANCE WITH PLANT TECHNICAL SPECIFICATIONS. |
+============================================================================+

+============================================================================+
|POWER REACTOR                                 |EVENT NUMBER:  29283         |
|FACILITY: LIMERICK                 REGION:  1 |LAST UPDATE DATE:  09/02/95  |
+----------------------------------------------------------------------------+
| TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO INOPERABILITY OF A        |
| POST-LOCA HYDROGEN RECOMBINER FOR MORE THAN 30 DAYS.                       |
+==


=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
Paul Smith <paul.smith@trobb.com>    (510) 547-0598 <FREE BBS, 8N1>
The Readiness Operation, Inc.       (510) 547-0594/0920 <voice/fax>    
What's a "Mailbot" for?  Send any message to mailbot@trobb.com to
learn what they are, how to use them, and how to get one. Send any
msg to infofile@trobb.com for info on 1,000s of NRC docs: FREE.
"Bit by bit and byte by byte, building the Utility InfoMarketplace"