[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: I-131 MCA Patient Room Decon
This may sound crazy but I use to used Kool Aid....(citric
acid)...please don't ask flavors...mike coogen
______________________________ Reply Separator _________________________________
Subject: I-131 MCA Patient Room Decon
Author: radsafe@romulus.ehs.uiuc.edu at ~GW1
Date: 2/13/96 8:23 AM
Our patient load has increased to the point to where we are seeking ways
to radiologically release our treatment rooms faster after the patient
has been released. We are primarily having problems with the toilet and
sink traps. We advise the patient to flush the toilet 3 times after use
and to rinse the sink for 30-45 seconds after use.We currently allow
Chlorox to remain in the bowl overnight. Is there any other methods we
might try or is anyone out there using any chemical means to expedite
cleanup. We currently allow Chlorox to remain in the bowl overnight. Mark
E. Campbell
Health Physicist Supervisor
Radiation Safety Division
University of Alabama at Birmingham
445 Community Health Services Building
933 South 19th Street
Birmingham, AL. 35294-2041
(205) 934-9345 - FAX (205) 934-7487