[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Management of highly radioactive human cadavers
What happened to the concept of dose limits to individual members of the
public? My copy of 10 CFR 20 says that I have to limit exposure to these
individuals to 100 millirem per year TEDE.
And what happened to the Clean Air Act - 10 millirem per person per year
limit from effluents.
Also note that I-131 is a medium energy beta emitter, which small
quantities in contact with the skin can cause significant exposure
(not to mention thyroid burdens from uptakes).
On Wed, 13 Mar 1996 Ragreen1@aol.com wrote:
> My OPINION is that since the workers are hardly likely to exceed 5 rem (50
> mSv), nothing needs be done.
>
> Regis A. Greenwood, C H P
Kent Lambert
LAMBERT@hal.hahnemann.edu
These are my thoughts. If they are wrong
I accidentally pressed the send instead of
the delete key. My employer makes no claim
to endorse my opinions.