RE: Rule of Thumb for BETA contamination




Shapiro (1990) offers the following (table 2.1):

Dose rate from 100 beta particles per second per cm-2 equals   approximately:

56 mrad/hr (C-14); 33 mrad/hr (Ca-45); 11 mrad/hr (P-32); 11 mrad/hr   (Sr-90).
Note:  Parallel beam (Jaeger, 1968, p. 14).

Tony Sorensen
Varian Oncology Systems
tony.sorensen@os.varian.com

 ----------
From:  radsafe[SMTP:radsafe@romulus.ehs.uiuc.edu]
Sent:  Thursday, October 02, 1997 6:41 AM
To:  Multiple recipients of list
Subject:  Rule of Thumb for BETA contamination

The rule of thumb conversion for removable contamination has been 1 mrem
gamma = 1 million dpm
assuming Co-60 as the major isotope does anyone have a rule of thumb for
1 mrem BETA ?

I'll welcome any input

Thanks,

M.B.
Mark Bedenbaugh
RNP- Ext. 1287
Beeper - 673-6040
mark.bedenbaugh@cplc.com

 ------ Message Header Follows ------
Received: from tdevil.os.varian.com by menlo_park.os.varian.com
  (PostalUnion/SMTP(tm) v2.1.9g for Windows NT(tm))
  id AA-1997Oct02.064157.1278.17302; Thu, 02 Oct 1997 06:41:57 -0700
Received: from falcon.varian.com by tdevil.os.varian.com   (SMI-8.6/SMI-SVR4)
 id GAA10890; Thu, 2 Oct 1997 06:49:05 -0700
Received: from postoffice.cso.uiuc.edu (postoffice.cso.uiuc.edu
[128.174.5.11])
by falcon.varian.com (8.6.8/8.6.6) with ESMTP id GAA24895 for
<tsorensen@os.varian.com>; Thu, 2 Oct 1997 06:50:02 -0700
Received: from romulus.ehs.uiuc.edu (romulus.ehs.uiuc.edu   [128.174.74.24])
 by postoffice.cso.uiuc.edu (8.8.5/8.8.5) with SMTP id IAA34078;
 Thu, 2 Oct 1997 08:46:21 -0500
Received: from localhost by romulus.ehs.uiuc.edu (NX5.67d/NeXT-2.0)
 id AA29955; Thu, 2 Oct 97 08:46:16 -0500
Date: Thu, 2 Oct 97 08:46:16 -0500
Message-Id: <9710021346.AA29955@romulus.ehs.uiuc.edu>
Errors-To: melissa@romulus.ehs.uiuc.edu
Reply-To: radsafe@romulus.ehs.uiuc.edu
Originator: radsafe@romulus.ehs.uiuc.edu
Sender: radsafe@romulus.ehs.uiuc.edu
Precedence: bulk
From: "Bedenbaugh, Mark" <mark.bedenbaugh@cplc.com>
To: Multiple recipients of list <radsafe@romulus.ehs.uiuc.edu>
Subject: Rule of Thumb for BETA contamination
X-Listserver-Version: 6.0 -- UNIX ListServer by Anastasios Kotsikonas
X-Comment:  Radiation Safety Distribution List