High Temperature Contamination Monitoring
Does anyone have information on techniques and/or materials for performing a loose surface contamination survey on a very hot stainless steel surface (1000 degrees Celsius)? Survey results will be used to release the object from a contamination area into a "clean" area. An indirect method (e.g., wipe) is necessary due to high background. The sample will be obtained remotely, and the wipe material should not prevent the detection of alpha-emitters. The contamination will consist of both alpha and beta-gamma emitting nuclides. Comments and suggestions welcome! Thanks
Mike Davidson
GTS Duratek
(410) 312-5121 voice
(410) 290-8154 fax
davidson@gtsduratek.com
Visit our website at www.gtsduratek.com !
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html