Re: Xenon-133 monitoring



> Is film used in occupational dosimetry practices very effective for
> monitoring exposure to Xenon-133 gas?

Dave,

The answer is no...  Even TLD is not used routinely to report 
occupational dose from Xe-133. Power reactors generally do dose 
calcs based on sampling, and assign a dose from that. The photon 
of 81 keV only has a 37% response. The beta max of .347 Mev will 
most likely not be detected by the film dosimeter.

I say rely on dose calcs for these exposures.

Sandy Perle
E-Mail: sandyfl@earthlink.net 
Personal Website: http://www.geocities.com/capecanaveral/1205

"The object of opening the mind, as of opening 
the mouth, is to close it again on something solid"
              - G. K. Chesterton -
************************************************************************