[ RadSafe ] Low background Shielding Material

john.gumnick at exeloncorp.com john.gumnick at exeloncorp.com
Thu Jun 8 17:44:17 CDT 2006


Cobalt-60 is used as a wear detector in blast furnace applications. Small Co-60 sources are embeded in the firebrick furnace lining at a known distance from the hotface. These are readily detectable from the outside of the furnace. When the liner has worn to a certain point the source disappears into the melt and is no longer detectable from the outside. A typical furnace might have 50 sources in the 1-5 mCi range embeded at various distances from the hotface, and a quick survey will tell you whether they're still in place or not. This technology has been used since the isotope became available for industrial applications, at least since the '50s.

John Gumnick, CHP
Exelon Nuclear
Corporate RP Technical Manager
630-657-2700

-----Original Message-----
From: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl]On
Behalf Of John R Johnson
Sent: Thursday, June 08, 2006 4:27 PM
To: chemitech at chemitech.com; radsafe at radlab.nl
Subject: RE: [ RadSafe ] Low background Shielding Material


Radsafers

Information on fallout is available in the UNSCREAR reports. They are at
http://www.unscear.org/unscear/en/publications.html

 _________________
John R Johnson, Ph.D.
*****
President, IDIAS, Inc
4535 West 9-Th Ave
Vancouver B. C.
V6R 2E2
(604) 222-9840
idias at interchange.ubc.ca



-----Original Message-----
From: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl]On
Behalf Of Marco Caceci
Sent: June 8, 2006 1:40 PM
To: radsafe at radlab.nl
Subject: RE: [ RadSafe ] Low background Shielding Material


I remember reading they find fallout Ru (Ru-106?) in new steel (from rain)
and of course Co60 etc. in recycled stuff. Sorry, no references, but it
makes sense.

Marco

-----Mensaje original-----
De: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl] En nombre
de Vernig, Peter G.
Enviado el: jueves, 08 de junio de 2006 17:09
Para: radsafe at radlab.nl
Asunto: [ RadSafe ] Low background Shielding Material


Group,

I have heard many times that "Pre World War II battleship steel" is used for
extremely low background shielding.  I had always wondered about that as it
seemed that an infinitesimal amount of fallout would find its way into
steel.  But then I heard another explanation that made more sense something
to do with the fabrication process that apparently changed post WWII and
involved a small amount of Co-60 I think.

Does anybody out there know what the explanation is?

Any opinions in this e-mail are solely those of the author, and are not
represented as those of the VA Eastern Colorado HCS, the Dept. of Veterans
Affairs, or the US Government.

Peter G. Vernig, Radiation Safety Officer, MS-115, VA Eastern Colorado
Health Care System, 1055 Clermont St. Denver, CO 80220, peter.vernig at va.gov,
Phone= 303.399.8020 x2447; Fax = 303.393.5026, alternate fax, 303.393.5248

"...whatever is true, whatever is noble, whatever is lovely, whatever is
admirable, if anything is found to be excellent or praiseworthy, let your
mind dwell on these things."

Paul of Tarsus

_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at:
http://radlab.nl/radsafe/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit:
http://radlab.nl/radsafe/

_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at:
http://radlab.nl/radsafe/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit:
http://radlab.nl/radsafe/

_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://radlab.nl/radsafe/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://radlab.nl/radsafe/

-----------------------------------------
*******************************************************************
*****
This e-mail and any of its attachments may contain Exelon
Corporation proprietary information, which is privileged,
confidential, or subject to copyright belonging to the Exelon
Corporation family of Companies.
This e-mail is intended solely for the use of the individual or
entity to which it is addressed.  If you are not the intended
recipient of this e-mail, you are hereby notified that any
dissemination, distribution, copying, or action taken in relation
to the contents of and attachments to this e-mail is strictly
prohibited and may be unlawful.  If you have received this e-mail
in error, please notify the sender immediately and permanently
delete the original and any copy of this e-mail and any printout.
Thank You.
*******************************************************************
*****




More information about the RadSafe mailing list