[ RadSafe ] RP issues with recovered uranium

Frik Beeslaar beeslaar at necsa.co.za
Wed Sep 5 06:27:05 CDT 2007


Dear Radsafers
 
I had a look at ASTM C1462 - Specifications for enrichment between 15%
and 20%.
There is no difference in the specifications whether commercial grade
enriched uranium metal is made from "fresh" natural uranium or recovered
uranium.  I am specifically thinking about the RP issues associated with
U232 and some of the fission products.  Can one assume that the RP
hazards will be on the same level whether it is made from fresh or
recovered uranium (taking into consideration one complies with this
standard - U232<0.002ug/gU)?
 
 
Regards and thanks
Frik Beeslaar
 
 
 
 

Frik Beeslaar

Radiation Protection Specialist

NECSA - SHEQ Department

www.necsa.co.za <http://www.necsa.co.za/> 

====================

( +27 (12) 305 3346

6 +27 (12) 305 3484

( +27 (82) 829 9613

* frik.beeslaar at necsa.co.za

====================


#####################################################################################
This e-mail message has been scanned for Viruses and Content and cleared 
by MailMarshal
#####################################################################################



More information about the RadSafe mailing list