Emil
Do you mean in (not on) a LSC?
I have done this many years ago (no paper written). You need to be able to
measure the K and L X-rays of Mn-55. The energies are K-sub alpha (5.90 keV,
100%; 5.89, 51%); K-sub beta (6.45keV, 16%). The percenatages are relative
to the K-sub alpha at 5.10 kev.
These photons do not excape the LS but produce electrons that are similar
in energy to those from tritium and if you can measure tritium you should be
able to measure Fe-55.
John
***************
John R Johnson, PhD
CEO, IDIAS, Inc.
4535 West 9th Ave
Vancouver, B. C.
V6R 2E2, Canada
idias at interchange.ubc.ca
----- Original Message -----
From: "Emil" <kerrembaev at yahoo.com>
To: <radsafe at radlab.nl>
Sent: Thursday, February 28, 2008 12:26 PM
Subject: [ RadSafe ] Fe-55 on LSC
> Greetings,
>
> I am wondering if somebody counted Fe-55 on LSC.
> I am trying to set LSC to count swipes to see how much Fe-55 in them.
>
> Thank you,
>
> Emil.
>
>
>
> ____________________________________________________________________________________
> Looking for last minute shopping deals?
> Find them fast with Yahoo! Search.
> http://tools.search.yahoo.com/newsearch/category.php?category=shopping
> _______________________________________________
> You are currently subscribed to the RadSafe mailing list
>
> Before posting a message to RadSafe be sure to have read and understood
> the RadSafe rules. These can be found at:
> http://radlab.nl/radsafe/radsaferules.html
>
> For information on how to subscribe or unsubscribe and other settings
> visit: http://radlab.nl/radsafe/
More information about the RadSafe
mailing list