[ RadSafe ] Re: Leak Test MDA - Amended
alstonchris at netscape.net
alstonchris at netscape.net
Thu Sep 24 17:21:44 CDT 2009
Kyle
Sorry about the careless error in my first msg. Please see below.
The figure you cite is the regulatory limit on removable activity, at which
you must remove the source from service, and repair it or dispose of it.
Clearly, if your MDA is not at least that low, you cannot demonstrate
compliance. I would?think that most people would prefer, operationally, to have
an MDA that is a relatively small fraction of the limit, so that you can act
before the fact, if a source appears to be failing. One reference is 10 CFR 35.67 (e).
Cheers
cja
-----Original Message-----
From: Harness, Kyle <kharness at ohmartvega.com>
To: radsafe at radlab.nl
Sent: Thu, Sep 24, 2009 9:06 am
Subject: [ RadSafe ] Leak Test MDA
Could someone please point me towards the reference(s) containing the
basis or calculation for the MDA of 0.005 microcuries in leak testing a
sealed source? I can't seem to find it anywhere. Or if you can't
remember the document, an explanation would suffice. Thanks in advance
for the million responses I am going to get on this!
Kyle Harness
Radiation Safety Officer
Ohmart/VEGA Corp.
4241 Allendorf Drive
Cincinnati, Ohio 45209 USA
[tel] 513.272.0524 ext. 211
[cell] 513.432.4504
[fax] 513.272.4390
www <http://www.ohmartvega.com/> .ohmartvega.com
KHarness at ohmartvega.com
_______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at: http://radlab.nl/radsafe/radsaferules.html
For information on how to subscribe or unsubscribe and other settings visit:
http://radlab.nl/radsafe/
_______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at: http://radlab.nl/radsafe/radsaferules.html
For information on how to subscribe or unsubscribe and other settings visit:
http://radlab.nl/radsafe/
More information about the RadSafe
mailing list