Hi Walt,

Perhaps my previous E-mail and yours crossed paths. I subsequently referenced whether or not the requirements of 2106 were in effect. I concur with your other comments as well.

As usual, good to hear from you!

Regards,

Sandy

-----------------------------------
Sander C. Perle
President
Mirion Technologies
Dosimetry Services Division
2652 McGaw Avenue
Irvine, CA 92614

+1 (949) 296-2306 (Office)
+1 (949) 296-1130 (Fax)

Mirion Technologies: http://www.mirion.com/



-----Original Message-----
From: Walt Cofer [mailto:radcontrol at embarqmail.com]
Sent: Wednesday, May 12, 2010 2:56 PM
To: Perle, Sandy
Cc: Daniel E' 'Hoffman; 'radsafe at health.phys.iit.edu'
Subject: Re: [ RadSafe ] 10 CFR 19.13(b)

Not so fast, Sandy.  The 2009 edition of 10 CFR 19.13(b) states that annual reports must only be issued to the monitored worker if the worker's dose exceeds 100 mrem or if the worker requests it.  The requirement is similar for termination dose reports - see 10 CFR 19.13(d)- they must only be provided upon request.  I read the rules to mean that the licensee must still issue annual and termination reports, but only has to provide them under the specified criteria.

As we all know, most workers immediately file their dose reports in the nearest waste bin, so the change makes sense.

Some, but not all Agreement States have adopted this rule change, so as always, an employer needs to know the rules they are subject to, in order to maintain compliance.

--
Walt Cofer
Radiation Control, Inc.
Tel:    (850) 668-8559
Cell:   (850) 519-5351
Email: radcontrol at embarqmail.com
Web:  www.rad-control.net

----- Original Message -----
From: Sandy Perle <SPerle at mirion.com>
To: Daniel E' 'Hoffman <Daniel.Hoffman at covidien.com>, 'radsafe at health.phys.iit.edu' <radsafe at health.phys.iit.edu>
Sent: Wed, 12 May 2010 17:30:15 -0400 (EDT)
Subject: Re: [ RadSafe ] 10 CFR 19.13(b)

Doug,

10CFR19.13(b) pertains to any worker monitored at the site during the annual period, regardless of their current status. If you provided dosimetry during the year, you are obligated to provide the individual with their dose record.

Regards,

Sandy

-----------------------------------
Sander C. Perle
President
Mirion Technologies
Dosimetry Services Division
2652 McGaw Avenue
Irvine, CA 92614

+1 (949) 296-2306 (Office)
+1 (949) 296-1130 (Fax)

Mirion Technologies: http://www.mirion.com/



-----Original Message-----
From: radsafe-bounces at health.phys.iit.edu [mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of Hoffman, Daniel E
Sent: Wednesday, May 12, 2010 2:26 PM
To: radsafe at health.phys.iit.edu
Subject: [ RadSafe ] 10 CFR 19.13(b)

Hello RadSafers.  I am curious how folks out there are interpreting the
subject regulation.  Specifically, does it apply to former workers or
only active workers?

Thanks for any feedback.

Dan Hoffman

Daniel E. Hoffman, CHP, CSP, CHMM
Radiation Safety Officer
Covidien
2703 Wagner Place
Maryland Heights, MO 63043
314-654-7906 (office)
314-625-1881 (cell)

_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu

PROPRIETARY INFORMATION NOTICE:   This e-mail message and all attachments transmitted with it are intended solely for use by the addressee and may contain proprietary information of Mirion Technologies and/or its affiliates.  If the reader of this message is not the intended recipient, you are hereby notified that any review, dissemination, distribution, copying or other use of this message is strictly prohibited.  If you have received this message in error, please notify the sender immediately by replying to the message, delete the original message and all attachments from your computer, and destroy any copies you may have made.  Thank you.
_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu


PROPRIETARY INFORMATION NOTICE:   This e-mail message and all attachments transmitted with it are intended solely for use by the addressee and may contain proprietary information of Mirion Technologies and/or its affiliates.  If the reader of this message is not the intended recipient, you are hereby notified that any review, dissemination, distribution, copying or other use of this message is strictly prohibited.  If you have received this message in error, please notify the sender immediately by replying to the message, delete the original message and all attachments from your computer, and destroy any copies you may have made.  Thank you.


More information about the RadSafe mailing list