[ RadSafe ] TLD and EPD dose comparisons (correction)

Perle, Sandy SPerle at mirion.com
Mon Feb 21 09:39:56 CST 2011


Correction below. The EPD can UNDER-RESPOND ii higher photon and lower
photon energies when calibrated to Cs-137 (looks like a bell-shaped curve).


Regards,

Sandy

-----------------------------------
Sander C. Perle
President
Mirion Technologies
Dosimetry Services Division
2652 McGaw Avenue
Irvine, CA 92614

+1 (949) 296-2306 (Office)
+1 (949) 296-1130 (Fax)

Mirion Technologies: http://www.mirion.com/



On 2/21/11 7:03 AM, "Perle, Sandy" <SPerle at mirion.com> wrote:

>You don't state what the issue is and the magnitude of difference between
>the TLD and EPD dose comparisons. Considerations:
>
> 1.  What work environment are the individuals working in?
> 2.  Are the difference that you are referring to collective dose or
>differences amongst individuals?
> 3.  What type of TLD and EPD are you using?
> 4.  What are the typical doses being observed that you're trying to
>compare?
> 5.  To what and how do you calibrate the TLD and the EPD?
> 6.  Are the calibration energies typical for the work area energies,
>both type of radiation and magnitude?
> 7.  Do you apply a correction factor to the EPD?
> 8.  What type of dose algorithm do you use for your TLD?
> 9.  Does the dose difference change during different types of work
>actives?
> 10. If you have an appropriate TLD dose algorithm, be cognizant that an
>EPD typically over-responds in giggler and lower photon energies, and if
>you're calibrating to a mid-range energy, such as Cs-137 and you're
>working in a much higher energy area, the EPD can over-respond.
> 11. Do you have much scatter? This could again be an algorithm and
>energy issue?
>
>Please provide additional information and support could be provided to
>you.
>
>Regards,
>
>Sandy
>
>-----------------------------------
>Sander C. Perle
>President
>Mirion Technologies
>Dosimetry Services Division
>2652 McGaw Avenue
>Irvine, CA 92614
>
>+1 (949) 296-2306 (Office)
>+1 (949) 296-1130 (Fax)
>
>Mirion Technologies: http://www.mirion.com/
>
>
>
>
>
>
>On 2/21/11 12:38 AM, "Ndanduleni Nephale"
><ndanduleni.nephale at necsa.co.za<mailto:ndanduleni.nephale at necsa.co.za>>
>wrote:
>
>We are using TLD as a primary dosimeter and EPD for dose management. We
>are always having a problem since the monthly results show a big
>different between TLD and EPD results. Is the anyway which your could
>compare the results of TLD and EPD?
>
>Ndanduleni Nephale
>Scientist
>Tel: +27 12 305 3396
>Fax: +27 12 305 3484
>Cell: +27 73 456 9404
>Email: mailto:ndanduleni.nephale at necsa.co.za
>Website: http://www.necsa.co.za/
>
>--------------------------------------------------------------------------
>This message contains confidential information and is intended only for
>the individual named. If you are not the named addressee you should not
>disseminate, distribute or copy this e-mail. Please notify the sender
>immediately by e-mail if you have received this e-mail by mistake and
>delete this e-mail from your system. E-mail transmission cannot be
>guaranteed to be secure or error-free as information could be
>intercepted, corrupted, lost, destroyed, arrive late or incomplete, or
>contain viruses. The sender therefore does not accept liability for any
>errors or omissions in the contents of this message, which arise as a
>result of e-mail transmission. If verification is required please request
>a hard-copy version from NECSA.
>
>
>
>##########################################################################
>###########
>Scanned by MailMarshal - M86 Security's comprehensive email content
>security solution.
>Download a free evaluation of MailMarshal at www.m86security.com
>##########################################################################
>###########
>_______________________________________________
>You are currently subscribed to the RadSafe mailing list
>
>Before posting a message to RadSafe be sure to have read and understood
>the RadSafe rules. These can be found at:
>http://health.phys.iit.edu/radsaferules.html
>
>For information on how to subscribe or unsubscribe and other settings
>visit: http://health.phys.iit.edu
>
>
>________________________________
>PROPRIETARY INFORMATION NOTICE: This e-mail message and all attachments
>transmitted with it are intended solely for use by the addressee and may
>contain proprietary information of Mirion Technologies and/or its
>affiliates. If the reader of this message is not the intended recipient,
>you are hereby notified that any review, dissemination, distribution,
>copying or other use of this message is strictly prohibited. If you have
>received this message in error, please notify the sender immediately by
>replying to the message, delete the original message and all attachments
>from your computer, and destroy any copies you may have made. Thank you.
>_______________________________________________
>You are currently subscribed to the RadSafe mailing list
>
>Before posting a message to RadSafe be sure to have read and understood
>the RadSafe rules. These can be found at:
>http://health.phys.iit.edu/radsaferules.html
>
>For information on how to subscribe or unsubscribe and other settings
>visit: http://health.phys.iit.edu
>
>PROPRIETARY INFORMATION NOTICE:   This e-mail message and all attachments
>transmitted with it are intended solely for use by the addressee and may
>contain proprietary information of Mirion Technologies and/or its
>affiliates.  If the reader of this message is not the intended recipient,
>you are hereby notified that any review, dissemination, distribution,
>copying or other use of this message is strictly prohibited.  If you have
>received this message in error, please notify the sender immediately by
>replying to the message, delete the original message and all attachments
>from your computer, and destroy any copies you may have made.  Thank you.


PROPRIETARY INFORMATION NOTICE:   This e-mail message and all attachments transmitted with it are intended solely for use by the addressee and may contain proprietary information of Mirion Technologies and/or its affiliates.  If the reader of this message is not the intended recipient, you are hereby notified that any review, dissemination, distribution, copying or other use of this message is strictly prohibited.  If you have received this message in error, please notify the sender immediately by replying to the message, delete the original message and all attachments from your computer, and destroy any copies you may have made.  Thank you.


More information about the RadSafe mailing list