[ RadSafe ] Dose Comparison Limits

Perle, Sandy SPerle at mirion.com
Mon Feb 21 11:02:07 CST 2011


Attachment includes all reference comparisons


ICRP 261 50 mSv (5rem)/yr

(108)2

5 mSv (0.5 mrem)/yr (119)

# 15 mSv (1.5 rem) Working condition B (116)

ICRP 60

20 mSv (2 rem)/yr, avged 5 yr

50 mSv (5 rem) in any year 100 mSv (10 rem) (total) in 5 yrs (166)

1mSv (0.1 rem)/yr Special circumstances of higher value, 5 yr average 1mSv (0.1 mrem) (192)

2 mSv (200 mrem) to surface of abdomen for remainder of pregnancy, limit intakes 1/20 ALI

(178)

ICRP 103

20mSv (2 rem)/yr, avged 5 yr 50 mSv (5 rem) in any year 100 mSv (10 rem)(total) in 5 yrs (183)

1 mSv (0.1 rem)/yr Special circumstances of higher value, 5 yr average 1mSv (0.1 rem) (191)

1mSv (100 mrem) to the embryo/fetus (186)

Part 20

50 mSv (5 rem)/yr ('20.1201(a)(1)(i))

1 mSv (0.1 rem)/yr Up to 5 mSv (500 mrem)/yr with prior NRC authorization ('20.1301(a)&(d))

5 mSv (0.5 rem) ('20.1208(a))

1 ICRP-2 was mentioned in the body of the Commission paper but not included in this comparison because it was fundamentally different than the other reports. The external limit for occupational workers was 5(N-18) rem, where N=the worker’s age. The internal dose was driven by the organ dose, which gave values of maximum permissible concentration based on organ dose rather than the effective dose. ICRP-2 did not contain any tissue or radiation weighting factors.

2 Paragraph number from the ICRP report cited as a reference source

EnclosureICRP 26


-----------------------------------
Sander C. Perle
President
Mirion Technologies
Dosimetry Services Division
2652 McGaw Avenue
Irvine, CA 92614

+1 (949) 296-2306 (Office)
+1 (949) 296-1130 (Fax)

Mirion Technologies: http://www.mirion.com/






On 2/21/11 8:17 AM, "Roy Parker" <radmail at cox.net<mailto:radmail at cox.net>> wrote:

What was the first year and publication in which ICRP established the 1 mSv annual limit for members of the general public?

Roy A. Parker, Ph.D.
Radiation Physics Consultant
_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu


________________________________
PROPRIETARY INFORMATION NOTICE: This e-mail message and all attachments transmitted with it are intended solely for use by the addressee and may contain proprietary information of Mirion Technologies and/or its affiliates. If the reader of this message is not the intended recipient, you are hereby notified that any review, dissemination, distribution, copying or other use of this message is strictly prohibited. If you have received this message in error, please notify the sender immediately by replying to the message, delete the original message and all attachments from your computer, and destroy any copies you may have made. Thank you.
-------------- next part --------------
A non-text attachment was scrubbed...
Name: enclosure-2.pdf
Type: application/pdf
Size: 73912 bytes
Desc: enclosure-2.pdf
URL: <http://health.phys.iit.edu/pipermail/radsafe/attachments/20110221/775cb5ee/attachment.pdf>


More information about the RadSafe mailing list