[ RadSafe ] Ra-226 Static Eliminator Bar

BRISSON Nicolas nicolas.brisson at irsn.fr
Fri Jul 8 05:18:38 CDT 2011


Hi all,

For once, I won't for help but try to bring a bit of information regarding the static eliminator bar I found.

Some colleagues carried out à gamma spectrometry using HpGe detector (20%, p-type).

Total activity results are given below :
radium 226 : 	75 Mbq +/- 25%
lead 214 :	34 MBq +/- 15%
bismuth 214 :	36 MBq +/- 15%



Nicolas Brisson
IRSN/DEI/SIAR
route du Panorama
92262 FONTENAY AUX ROSES
tel : +33 1-58-35-87-24
por :  +33 6-08-76-55-32



-------------------------------------------------------------------------------------------------------

From:   "BRISSON Nicolas" <nicolas.brisson at irsn.fr>
To:     "The International Radiation Protection \(Health Physics\) 
MailingList" <radsafe at health.phys.iit.edu>
Date:   04/12/2011 10:06 AM
Subject:        [ RadSafe ]  Ra-226 Static Eliminator Bar
Sent by:        radsafe-bounces at health.phys.iit.edu




Hi all,

 

2 years ago we had a short discussion about radium-226 static eliminator 
bar (excerpt below).
At that time I could only find the article mentioned below.

 
Last week I found a static eliminator bar from US Radium Corp. 

 
As the dose rate ranged from 1 mSv/h to 1,6 mSv/h between 5 and 0 cm from 
the bar, we didn’t spend too much time studying it at close range. So I 
would be interested in layouts or any information available about these 
bars

 

Thanks,

 
Nicolas Brisson
IRSN/DEI/SIAR
route du Panorama
92262 FONTENAY AUX ROSES
tel : +33 1-58-35-87-24
por :  +33 6-08-76-55-32


--------------------------------------------------------------------------------

From: BRISSON Nicolas <nicolas.brisson at irsn.fr>
To: radsafe at radlab.nl
Sent: Wed, 28 October, 2009 20:58:57
Subject: TR: [ RadSafe ] Ra-226 Static eliminator bar

Hello all,


I don't have much information on this topic but you can find an article at 
the web address below.
American Journal of Public Health (August 1950) :

            http://www.ajph.org/cgi/reprint/40/8/943.pdf 



In this article you can read that these static eliminator bars contained 
25 or 50 µg of radium 226 per linear inch.
Some Ionotron with radium 226 were manufactured by US Radium Corps.

In France, you could buy a ionotron t.200 for around 20€ in 1960. 
For a total length of 15 cm, the active part had a length of 5 cm. In the 
safety sheet given with the ionotron, it was said that you were at the 
safe distance from the ionotron at 25 cm. Remember though that it was in 
1960...





_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood 
the RadSafe rules. These can be found at: 
http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings 
visit: http://health.phys.iit.edu


_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu


More information about the RadSafe mailing list