[ RadSafe ] Ra-226 Static Eliminator Bar
alstonchris at netscape.net
alstonchris at netscape.net
Fri Jul 8 17:01:33 CDT 2011
Nicolas
I do not have a table of half-lives to hand, and I am ashamed to say that I no longer remember the basic U-238 decay chain, but, should the Lead and Bismuth be in equilibrium? I mean to say, is the device leaking?
I await the slings and arrows with equanimity.
Cheers
cja
-----Original Message-----
From: BRISSON Nicolas <nicolas.brisson at irsn.fr>
To: The International Radiation Protection (Health Physics) MailingList <radsafe at health.phys.iit.edu>
Sent: Fri, Jul 8, 2011 8:24 am
Subject: Re: [ RadSafe ] Ra-226 Static Eliminator Bar
Hi all,
For once, I won't for help but try to bring a bit of information regarding the
static eliminator bar I found.
Some colleagues carried out à gamma spectrometry using HpGe detector (20%,
p-type).
Total activity results are given below :
radium 226 : 75 Mbq +/- 25%
lead 214 : 34 MBq +/- 15%
bismuth 214 : 36 MBq +/- 15%
Nicolas Brisson
IRSN/DEI/SIAR
route du Panorama
92262 FONTENAY AUX ROSES
tel : +33 1-58-35-87-24
por : +33 6-08-76-55-32
-------------------------------------------------------------------------------------------------------
From: "BRISSON Nicolas" <nicolas.brisson at irsn.fr>
To: "The International Radiation Protection \(Health Physics\)
MailingList" <radsafe at health.phys.iit.edu>
Date: 04/12/2011 10:06 AM
Subject: [ RadSafe ] Ra-226 Static Eliminator Bar
Sent by: radsafe-bounces at health.phys.iit.edu
Hi all,
2 years ago we had a short discussion about radium-226 static eliminator
bar (excerpt below).
At that time I could only find the article mentioned below.
Last week I found a static eliminator bar from US Radium Corp.
As the dose rate ranged from 1 mSv/h to 1,6 mSv/h between 5 and 0 cm from
the bar, we didn’t spend too much time studying it at close range. So I
would be interested in layouts or any information available about these
bars
Thanks,
Nicolas Brisson
IRSN/DEI/SIAR
route du Panorama
92262 FONTENAY AUX ROSES
tel : +33 1-58-35-87-24
por : +33 6-08-76-55-32
--------------------------------------------------------------------------------
From: BRISSON Nicolas <nicolas.brisson at irsn.fr>
To: radsafe at radlab.nl
Sent: Wed, 28 October, 2009 20:58:57
Subject: TR: [ RadSafe ] Ra-226 Static eliminator bar
Hello all,
I don't have much information on this topic but you can find an article at
the web address below.
American Journal of Public Health (August 1950) :
http://www.ajph.org/cgi/reprint/40/8/943.pdf
In this article you can read that these static eliminator bars contained
25 or 50 µg of radium 226 per linear inch.
Some Ionotron with radium 226 were manufactured by US Radium Corps.
In France, you could buy a ionotron t.200 for around 20€ in 1960.
For a total length of 15 cm, the active part had a length of 5 cm. In the
safety sheet given with the ionotron, it was said that you were at the
safe distance from the ionotron at 25 cm. Remember though that it was in
1960...
_______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood
the RadSafe rules. These can be found at:
http://health.phys.iit.edu/radsaferules.html
For information on how to subscribe or unsubscribe and other settings
visit: http://health.phys.iit.edu
_______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html
For information on how to subscribe or unsubscribe and other settings visit:
http://health.phys.iit.edu
_______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html
For information on how to subscribe or unsubscribe and other settings visit:
http://health.phys.iit.edu
More information about the RadSafe
mailing list