 Very well said Glenn;It will take a while to respond to emergencies if someone have to take a pause to think about the units which you're not familiar with versus units used everyday for last 20 years or so.


Maha Srinivasan 

________________________________________ 
Health Physicist & Radiation Safety Officer 
Wayne State University 
5425 Woodward Ave,Ste 300 
Detroit, Michigan 48202 
Phone: 313-577-0019 
Fax: 313-993-4079 

www.oehs.wayne.edu 
 

----- Original Message -----
From: "Glenn R. Marshall" <GRMarshall at philotechnics.com>
To: "The International Radiation Protection (Health Physics) Mailing List" <radsafe at health.phys.iit.edu>
Sent: Tuesday, March 29, 2011 8:52:20 AM
Subject: Re: [ RadSafe ] SI Purists

Conventional units are not obsolete.  They are perfectly good units in that they quantify dose and amount of radioactivity.  

As RSO, I have a great responsibility to my coworkers, my employer, and the general public to ensure our work is performed safely and radiation doses are below limits and ALARA.  Those who know me know I take it seriously (even though I gripe about all the paperwork I have to generate, but that's beside the point).  Often, I have to know instantly whether or not the data I am looking at means we have a problem and, if so, the magnitude of it.  For more than 30 years I have conditioned my brain to think in terms of rem, rad, and Curie.  

When I look at an air sample result and it says we have 2E-9 uCi/ml of Am-241, I instantly know there is a big problem.  But if it says we have 70 Bq/m^3, I have no idea whether or not that's a problem "off the top of my head", because I don't think in those units.  

When I train our workers, I intentionally make sure everything is in conventional units.  It's hard enough for the average worker to grasp the concept of mrem and uCi; there is no way I'm going to now start throwing uSv, mBq, and mGy at them.

I know the SI units; I'm just not used to working with them.  So for me, to be forced to change now would compromise my effectiveness, and possible the health and well-being of the people I work with and care about.

 
Glenn Marshall, CHP
 
-----Original Message-----
From: radsafe-bounces at health.phys.iit.edu [mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of Philip Simpson
Sent: Monday, March 28, 2011 8:41 PM
To: The International Radiation Protection (Health Physics) Mailing List
Subject: [ RadSafe ] SI Purists

I have been reading the "traditional vs. SI units"  thread with amusement for the past couple of weeks. Having worked at a research reactor for 30+ years here's my two pence worth.

First a nit to pick:  If we're doing SI lets get it right!  When using Gy and Sv, then dose rate and exposure rates should be always be given in units Gy/s and Sv/s. Otherwise we have mixed units in the same number (hours and seconds) and, if I remember my Chemistry 113 instructor correctly, that's a no-no in SI.

Trading Rad and Rem for Gy and Sv are not like coming to terms with Ci or Bq - the last definition I saw for a Rad had it based on the metric system just like the Gy. Why trade 100 ergs for 1000 g? Just to make it fit nicely into the mks system versus the cgs system? The mks system may work fine for a car crashing into a barrier or, a little closer to home, that Pb brick you just pinched your finger with, but it stinks for radiation measurements.

Call me a troglodyte but, life sure was easy when the annual exposure limit was 5 Rem as opposed to 50mSv.  It was a simple rule-of -thumb that I could work all day, every day (8 hour days) in a 1 mR/hr gamma field and not come close to exceeding the dose limits. (My RSO, however,  would probably question my monthly exposure readings.) Likewise, I sure better stop, step back, and think about things when I pull a sample out of the pool and my ion chamber (held at arms length) passes 1 R/hr.  After all, only 5 hours exposure and I'm at the annual dose limit!

For me, nice round numbers such as 5 Rem and 1 mRem/hr are a lot easier to instantly recognize, understand and conceptualize than 0.05 Sv, 50 mSv, 10 µSv, etc. The Rad and Rem are "ergonomic".  The Gy and Sv are not.  Maybe it is just teaching and training but I'm not so sure. 

Will I work with the Gy and Sv? Yes, because I am forced to by the rest of the World.  But, I won't apologize for preferring the Rad and Rem. There are circumstances where the American way is the better way.

Phil Simpson, Assistant Mgr.(Ret.)
University of Michigan
Ford Nuclear Reactor



_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu
_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu

-- 









More information about the RadSafe mailing list