[ RadSafe ] potentially combustible helium (Article Explained)

Roger Helbig rwhelbig at gmail.com
Tue Jan 3 17:22:05 CST 2012


The article explained it very well - and it was about the potential
problems of fighting a fire in an MRI unit which were averted by quick
thinking hospital technician

MRI fire underscores need for education and oversight
December 30, 2011

By Tim Darragh, Of The Morning Call

...kept in operation by super-cooled liquid helium and use enormous
amounts of energy. The liquid helium ? cooled to 450 degrees below
Fahrenheit...thermos" casing, he said, the liquid helium could have
escaped, and immediately chilled...

Nancy Run Fire Company Chief Jamie Hauze said the cause of the fire
still is under investigation. He also said that while the response to
the fire ended up being routine, the threat posed by the fire was
anything but that.

"It just happened to be in the worst place possible," he said.

MRIs employ strong magnets kept in operation by super-cooled liquid
helium and use enormous amounts of energy. The liquid helium — cooled
to 450 degrees below Fahrenheit — essentially keeps the electric
current continuously alive, said Tobias Gilk, president and safety
director for Mednovus, an MRI safety company. If a fire were to have
pierced the "thermos" casing, he said, the liquid helium could have
escaped, and immediately chilled the oxygen in the environment to
liquid, creating a highly explosive scene.

"Any spark or flame in the presence of liquid oxygen becomes virtually
inextinguishable until the oxygen burns out," he said.

Even without a puncture, fire could warm the liquid helium to a
gaseous state, causing the helium to expand and result in a
potentially disastrous buildup in pressure.

Those scenarios did not occur because a St. Luke's MRI technologist
activated a system that "quenched" the unit, according to Hauze and
St. Luke's spokeswoman Dorrit Trate. Essentially, the process
demagnetizes the unit by allowing the gaseous helium to escape safely
through a chimney-like vent into the outside atmosphere.

It was only then that firefighters, who were made aware of the
potential hazards of the MRI during inspections of the hospital before
it opened, could put out the fire.

The MRI had to be quenched because much of the equipment that fire
fighters carry — axes, picks, oxygen tanks and more — contains ferrous
material and would have been sucked into the unit by its magnetic
force. Their equipment, and anything metal, could have become
MRI-seeking missiles, as other firefighters have learned. According to
Gilk, a firefighter in Stockton, Calif., last year lost his ax to the
pull of an the MRI while he was ventilating the roof a building.




On Tue, Jan 3, 2012 at 11:48 AM, Brennan, Mike  (DOH)
<Mike.Brennan at doh.wa.gov> wrote:
> The chemistry education of everyone involved in the press release and
> article should also be under investigation.  I'd have spotted the
> problem with this article in junior high school, or possibly grade
> school.
>
> -----Original Message-----
> From: radsafe-bounces at health.phys.iit.edu
> [mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of FISHER Spencer
> -NUCLEAR
> Sent: Tuesday, January 03, 2012 11:42 AM
> To: 'radsafe at agni.phys.iit.edu'
> Subject: [ RadSafe ] potentially combustible helium??????
>
> MRI safety training pays off in Pa.
> By AuntMinnie.com staff writers
> January 3, 2012
>
> Officials at St. Luke's Hospital - Anderson Campus in Easton, PA, are
> crediting MRI safety training as the reason injuries and extensive
> damage were avoided following a fire in an MRI suite at the facility.
>
> A December 30
> report<http://www.mcall.com/health/mc-bethlehem-mri-explosions-20111230,
> 0,7840341.story> in the Morning Call newspaper noted that no one was
> injured at St. Luke's, and damage was limited to smoke in the hallways.
> An MRI technologist activated a system that demagnetized the unit and
> allowed potentially combustible helium to exit the building through a
> vent, according to the report. At that point, firefighters were able to
> extinguish the fire.
> The cause of the incident is under investigation.
>
>
>
>
> -----------------------------------------
> THIS MESSAGE IS ONLY INTENDED FOR THE USE OF THE INTENDED
> RECIPIENT(S) AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED,
> PROPRIETARY AND/OR CONFIDENTIAL. If you are not the intended
> recipient, you are hereby notified that any review, retransmission,
> dissemination, distribution, copying, conversion to hard copy or
> other use of this communication is strictly prohibited. If you are
> not the intended recipient and have received this message in error,
> please notify me by return e-mail and delete this message from your
> system. Ontario Power Generation Inc.
> _______________________________________________
> You are currently subscribed to the RadSafe mailing list
>
> Before posting a message to RadSafe be sure to have read and understood
> the RadSafe rules. These can be found at:
> http://health.phys.iit.edu/radsaferules.html
>
> For information on how to subscribe or unsubscribe and other settings
> visit: http://health.phys.iit.edu
> _______________________________________________
> You are currently subscribed to the RadSafe mailing list
>
> Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html
>
> For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu


More information about the RadSafe mailing list