[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Donning a Respirator inside a CA
Please give me your opinion on donning a respirator while inside a CA.
PFP Hanford has employees working in Pu gloveboxes which are located in
rooms that are posted as Contamination Areas (CAs). The majority of surface
areas in these areas are <20 dpm/100cm2, but there are isolated areas up to
2,000 dpm/100cm2. The workers wear 1-pair of booties and 1-pair of
shoecovers, (taped), 2-pairs of gloves (inner are taped), and coveralls; no
hood. If waste or product needs to be sealed-out of the glovebox, the room
(airspace) needs to be placed on Airborne Radioactive Area (ARA) status.
Presently, to do this, the employees exit the CA, survey and re-dress with
the same protective clothing plus a respirator and hood (taped).
The proposed plan would be to use the same logic as found in the DOE RadCon
Manual, Article 342.11. It allows drinking water in a CA if the workers
hands and faces are monitored for contamination prior to drinking. The
proposed PFP plan would be to have the workers change their outer gloves and
either self monitor or have a RCT monitor the workers hands, face and head.
If clean, the workers would remove a respirator from its bag, don it, then
put on a hood and tape it to the respirator.
Does anyone see a down side to this plan?
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html