RE: Compensation of survivors (Lead Apron Dosimetry)



> Just a personal observation.



And very accurate Les. We provide the ANSI N13.41-1997 dose 

weighting, as well as Niklasson and Webster. What many of these 

facilities fail to realize is that no matter what dose weighting you 

use, the lens dose has to come from a collar dosimeter, as well as a 

way to calculate the highest dose to the un-protected skin. Many 

thing that dose weighting mitigates the higher doses. It does not.



Thank you for stating the issue and the requirements so well.



------------------------------------------------------------------------

Sandy Perle					Tel:(714) 545-0100 / (800) 548-5100   				    	

Director, Technical				Extension 2306 				     	

ICN Worldwide Dosimetry Service		Fax:(714) 668-3149 	                   		    

ICN Pharmaceuticals, Inc.			E-Mail: sandyfl@earthlink.net 				                           

ICN Plaza, 3300 Hyland Avenue  		E-Mail: sperle@icnpharm.com          	          

Costa Mesa, CA 92626                    



Personal Website: http://www.geocities.com/scperle

ICN Worldwide Dosimetry Website: http://www.dosimetry.com



************************************************************************