[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: external dose evaluation



Bill,



I currently am providing the ANSI N13.41-1997 effective dose weighting calculation in one SE 

state (not under NRC jurisdiction). This method does result in a higher dose than most of the other 

dose weighting methodologies.



The NRC has been considering the use of dose weighting, even sponsored the EPRI Meeting 

back in 1997. Unfortunately they have not moved on it. Hopefully now they will allow use of the 

various methodologies, as you outlined. I can currently provide the Webster (99%), Niklasson (1 

client) and the N13.41 (1 client).



Dose evaluations will obviously change for the better.

------------------------------------------------------------------------

Sandy Perle				Tel:(714) 545-0100 / (800) 548-5100   

Director, Technical			Extension 2306

ICN Worldwide Dosimetry Service	Fax:(714) 668-3149 	           

ICN Pharmaceuticals, Inc.		E-Mail: sandyfl@earthlink.neI

ICN Plaza, 3300 Hyland Avenue  	E-Mail: sperle@icnpharm.com   

Costa Mesa, CA 92626                    



Personal Website: http://sandyfl.nukeworker.net

ICN Worldwide Dosimetry Website: http://www.dosimetry.com





************************************************************************

You are currently subscribed to the Radsafe mailing list. To unsubscribe,

send an e-mail to Majordomo@list.vanderbilt.edu  Put the text "unsubscribe

radsafe" (no quote marks) in the body of the e-mail, with no subject line.