Re: external dose evaluation
Bill,
I currently am providing the ANSI N13.41-1997 effective dose weighting calculation in one SE
state (not under NRC jurisdiction). This method does result in a higher dose than most of the other
dose weighting methodologies.
The NRC has been considering the use of dose weighting, even sponsored the EPRI Meeting
back in 1997. Unfortunately they have not moved on it. Hopefully now they will allow use of the
various methodologies, as you outlined. I can currently provide the Webster (99%), Niklasson (1
client) and the N13.41 (1 client).
Dose evaluations will obviously change for the better.
------------------------------------------------------------------------
Sandy Perle Tel:(714) 545-0100 / (800) 548-5100
Director, Technical Extension 2306
ICN Worldwide Dosimetry Service Fax:(714) 668-3149
ICN Pharmaceuticals, Inc. E-Mail: sandyfl@earthlink.neI
ICN Plaza, 3300 Hyland Avenue E-Mail: sperle@icnpharm.com
Costa Mesa, CA 92626
Personal Website: http://sandyfl.nukeworker.net
ICN Worldwide Dosimetry Website: http://www.dosimetry.com
************************************************************************