[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Powernet: Re: I submitted the "primary" versus "secondary"dosimeter(follow-up)
On 6 May 2003 at 12:25, William V Lipton wrote:
> The problem is that lapel samplers do not currently require "processing."
> With that exclusion taken away, it seems that they would require NVLAP
> evaluation. Is there a standard for this?
My petition does not change what is currently in the regulation
regarding lapel samplers. NVLAP does not cover lapel samplers. ANSI
N13.11-2001 does not cover lapel samplers.
> In general, while your intent may be worthwhile, the "(1) ready, (2) fire,
> (3) aim" approach in this petition concerns me.
I disagree with your assertion above. My petition was well thought
out, and I consulted with many individuals before submitting it. It
was also reviewed by several high placed NRC individuals before
submittal. I am directing my petition at common dosimeters used today
to derive dose of record, that are currently tested under NVLAP and
are included in ANSI N13.11-2001 and ANSI N13.32-1995 (to be revised
and issued in late 2003 or early 2004). What I have stated is already
being tested, in a voluntary scenario. I am only asking to make the
voluntary non-voluntary.
As Bob Flood said yesterday, there is no reason why a processor who
accredits their whole body system would not accredit their extremity
monitoring system.
The requirements as stated are needed, and as a NVLAP assessor, I see
more reasosn every time I do an assessment where this proposal really
needs to be implemented.
Thanks ...
-------------------------------------------------
Sandy Perle
Director, Technical
ICN Worldwide Dosimetry Service
ICN Plaza, 3300 Hyland Avenue
Costa Mesa, CA 92626
Tel:(714) 545-0100 / (800) 548-5100 Extension 2306
Fax:(714) 668-3149
E-Mail: sandyfl@earthlink.net
E-Mail: sperle@icnpharm.com
Personal Website: http://sandy-travels.com/
ICN Worldwide Dosimetry Website: http://www.dosimetry.com/
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.
You can view the Radsafe archives at http://www.vanderbilt.edu/radsafe/