Re: Plasma Torch Cutting
Plasma cutting was used in the Peach Bottom Unit 1 End Of Life program.
The steam generator was opened using plasma cutting and the steam
generator tubes were removed for sampling purposes. PECO should still
have the report. The work was done by Catalytic for General Atomic in
San Diego in the mid 70's. The plasma arc cutting generated large
amounts of airborne iron oxide. HEPA filters clogged up frequently and
the continuous air monitor would load up very quickly. Actual airborne
radioactivity was not a major problem, but monitoring it was. Both
Cs-137 and Sr-90 were the contaminants. I planned the radiological
safety program, but was not on site for the actual work.
John Andrews
Knoxville, Tennessee
Dave Biela wrote:
>We are doing some work using a plasma cutter on contaminated stainless
>steel and would like to discuss lessons learned with others who have
>used this method.
>
>One of the main questions is: What were your ratios of airborne
>contamination concentrations in the work area to contamination levels on
>the cut surfaces?
>
>If your interested in a discussion, contact me directly at
>dave.biela@wvnsco.com or
>716-942-4423
>
>Thanks
>Dave Biela
>
>
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.