[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: PCs and Tritium
Greetings from sunny Raleigh, N.C.:
The Lb5100 with the thin window (80 micrograms per sq. cm.) also has
an air gap of about 6 mm. Together this gives about 0.85 mg/sq.cm.
Look at range vs. energy in the Rad. Health Handbook and you'll see
that you are pretty close to the cutoff for Emax. Better try LSC.
Ralton J. Harris
NCSU
*North Carolina State University*Environmental Health & Safety Center*
----------------------------------------------------------------------
: Ralton J. Harris | Bill Crocker :
: Environmental Health Physicist | Radiological Health Specialist :
: (919)515-5212 | (919)515-5214 :
:--------------------------------------------------------------------:
: RALTON_HARRIS@NCSU.EDU | BILL_CROCKER@NCSU.EDU :
:--------------------------------------------------------------------:
******* Radiation Protection Office*Box 7108*Raleigh,NC*27695 ********