[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Tritium Bubblers
>
>I'm looking for someone who may have first hand knowledge or at least be
>able to point me towards a good reference regarding the theory behind the
>tritium bubbler air sampler's operation (i.e. relationship of flowrate
>and volume to collection efficiency and the actual mechanism by which
>tritium is transfered from the air to the water volume).
>
>Thanks in advance for you assistance!
>
>Kirk Brewer, Health Physicist
>APS-Palo Verde Nuclear Generating Station
>(602)-393-6095
>kbrewer@indirect.com
>
>Disclaimer:
>The views and opinions expressed here are that of the individual and are
>in no way respresentative of APS Company or its representatives.
>
>
We have extensive experience in monitoring for tritium in all types of
systems. We currently maintain inventory levels of approximately 100k Curies
of tritium on site. We use real time and passive types of monitoring
systems for detection of tritium in our systems. The passive monitoring
types include bubblers and "DATS". Both of these systems are discriminating
allowing for the detection of oxide as well as elemental tritium. We have
built, calibrated, and tested bubblers using both water and other transfer
materials. Our HP field operations group uses bubblers on a daily basis.
If you are interested in our experiences give me a call. It would take
volumes to e-mail specific information.
George Ascione
Deputy Manager, Health Physics
Princeton Plasma Physics Laboratory
Princeton NJ.
609-243-2513 Voice
609-243-2525 Fax