Re: Samarium-153 -Reply
>A question about dose rate constants came up in our group recently.
>
>Does anyone have an opinion on what the real value is (i.e. with
>an error bar somewhat less than a factor of two)? Is there this much
>scatter in reported values for other low energy emitters?
The values I've been using are
Pd-103: 1293 mrem*cm^2/hr/mCi (provided by manufacturer)
I-125: 1270 mrem*cm^2/hr/mCi (provided by manufacturer AND
confirmed by measurement using a Bicron
MicroRem/Low Energy survey meter calibrated
using Cs-137 sources, and a 10 mCi point source
purchased from Amersham)
I-125: 1450 mR*cm^2/hr/mCi (provided by manufacturer; I don't
really use this number, but I keep it handy).
Albert Lee Vest avest@magnus.acs.ohio-state.edu
Health Physicist Environmental Health and Safety
(614)292-0122 The Ohio State University
My employer did not review or approve this message.