Re: ELF Effects on VDUs



> Did you measure using a broadband probe?  

I used a Teslatronics Model 70 triaxial ELF Gauss meter. Its response drops
by 3dB at 30 and 600Hz.

>Were you measuring harmonics with the 50Hz?

Yes.

Thanks to all who responded. I will have to try the tea trolley strategy!!

Regards



                        Alex Zapantis
                        Radiation Safety Officer                               
                        Queensland University of Technology          
                        Health & Safety Section                             
                        Locked Bag No.2
                        Red Hill Qld 4059
                        AUSTRALIA

                        Ph     : 61 7 864 3566
                        fax     : 61 7 864 3993
                        email  : a.zapantis@qut.edu.au