The info regarding calculating a DDE based on weighting factors for one badge
worn outside of a .5mm lead apron, and one worn inside is:
H(E) = 1.5 x badge reading of dosimeter worn at waist under apron
+ .004 x badge reading of dosimeter worn outside apron at neck level.
This is formula and supporting documentation is found in the Correspondence
section of a 1994 HPS Journal. I have just kept a photocopy of the two
pages, and those pages don't say what issue it is. However, it does
reference: 0017-9078/94
If you want a copy faxed, write to me directly