patient dental exposure
Multiple recipients of list
For lateral adult bitewing the Entrance Skin Exposure, ESE, will
range from 50 to 575 mR depending on the kVp used and wheather the
film is D or E speed. Example: For a 70 kVp technique using D speed
film which is properly developed the ESE will be in the range 249 to
350 mR.
The Total Effective Dose Equivalent for a 2 film intraoral procedure
will be only a few mrem: definitely less than 5 mrem.(see 1985,
British Journal of Radiology,56, 511-516.)
Richard B. Sanborn