Re: Shallow Dose Calculation from low energy photons



PHOTCOEF will do the job.
(http://www.photcoef.com)

Paul Kehler


At 05:00 PM 11/12/96 -0600, you wrote:
>I would like to estimate the shallow dose to the skin from a skin
>contamination event where the contaminant emits low energy photons, say
>10 to 60 keV.  I am aware of the use of VARSKIN for estimating dose from
>beta contamination.  Is there a similar code for low energy photons?  
>
>I have done the point source calculations from first principles, but I
>want to calculate the dose to a larger area from a distributed source. 
>I would appreciate any pointers to references for this type of
>calculation.  
>
>Thanks in advance.
>-- 
>Mike Lewandowski
>Westinghouse/WIPP      voice(505)234-8419
>PO Box 2078, MS-145    mikelew@tis.eh.doe.gov
>Carlsbad, NM  88221    Opinions expressed in this message are my own.
>
>
>
>