[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
N16 response clarification
I was informed that me earlier response was not quite clear, and in
fact, was misleading. The following were the results of our N16
study:
Eberline Digidose Electron Dosimeter: + 5.3%
Merlin Gerin Electronic Dosimeter: + 10.8%
Panasonic UD802AT TLD: gamma +2.9%
Hd + 10.6%
Hs + 22.5%
He + 9.6%
Hope this clarifies the study we did in 1993.
------------------