[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: dose conversion
My original post started with the "from" word and got cut off. Here it
is again
> Charles Meyer wrote:
> >
> > I need to make a shipment of Sr-90, the only indicator of activity
> > that I have is an old calibration stating that the eye applicator
> > delivered 78 beta rads per second as of 12/17/65.
> >
> > Anyone know how the dose rate was calculated and I can back calculate
> > into a reasonable estimate of the activity?
> > <><><><><><><><><><><><><><><><><>
> > <> Charles R. (Russ) Meyer <>
> > <> Email: cmeyer@brc1.tdh.state.tx.us <>
> > <> Phone:(512)834-6688 <>
> > <> Fax:(512)834-6654 <>
> > <><><><><><><><><><><><><><><><><>
>
> Charles and All,
>
> >Well, from my files, I find that a 100 mCi Sr-90 eye applicator beta source
> was rated at 56 rad/sec.
>
> cheers, Wes
>
--
Wesley R. Van Pelt, Ph.D., CIH, CHP KF2LG
President, Van Pelt Associates, Inc.
Consulting in radiological health and safety.
mailto:VanPeltW@IDT.net