[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Instrumentation for Emergencies -Reply
49 CFR 173.441 (b) (1) Closed transport vehicle under exclusive use transport
can have a package max. reading of 10 mSv/h (1000 mrem/h).
Alan R. Marchand
radarm@accessnv.com
At 03:50 PM 8/7/98 -0500, you wrote:
>1. Do not let radiological concerns in any way increase the risk of serious
>injury or death. Physical inuries are certain, risk of death from cancer is
>comparably insignificant.
>
>2. An ion chamber such which would enable open and closed windows would be
the
>best single instrument. A GM frisker would only needed for insignificant
>amounts of radioactivity (i.e. clean-up after first response).
>
>3. The most probable event in which materials would be released would be a
LSA
>package (~200mrem/hr), not a cask. LSA packages are held to standards that
are
>not comparable to a cask shipment.
>
>5 minute time limit is up... good luck!
>
>Sincerely,
>Glen Vickers
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html