[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Shallow Doses from Pu-238 Operations



At 11:04 AM 3/15/99 -0600, you wrote:
>Brian Gaulke
>03/15/99 11:55 AM
>
>Section 4.8 of PNL-6534, "Health Physics Manual of Good Practices for
>Plutonium Facilities", may provide you with adequate information to
>calculate such doses. 

Related to Brian's suggestion, an "updated' Guide of Good Practices Document was prepared by DOE in the form of DOE-STD-1128-98, "Guide of Good Practices for Occupational Radiological Protection in Plutonium Facilities" (June 1998).

Copies of the Standard are also available from the DOE Technical Standards Program Internet site (http://apollo.osti.gov/html/techstds/techstds.html).

Regards,
erik


________________________________________
Erik F. Shores
Los Alamos National Laboratory
ESH-12, Radiological Engineering Team
Mailto:eshores@lanl.gov
505.665.7643 (phone)
505.667.9726 (facsimile)