[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Sr-90 Source Activity/Geometry -Reply
Sumimasen, but I think the total activity might be underestimated by 1/2 using
this approach.
Assume calibration yields an instrument response of 200 cps. The calibration
factor using only the Sr-90 activity (802 Bq) becomes 4.01 Bq/cps or 0.249
cps/Bq.
Does this mean you would report a sample's total activity (with Sr-90 and Y-90
in equilibrium) as 8020 Bq for an instrument response of 2000 cps? Some
Regulators might disagree.
Jack McCarthy
mccarjl@gwsmtp.nu.com
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription