[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: P-32 exposure
> Your concerns are justified. We have had a number of
> investigators labeling cells with large (>40 mCi) of P-32 and did
> work with them to reduce their hand exposure.
>
I have done a number of these types of experiments and in some cases P-32
must be used although I would rather use P-33. One additional item is to
use an incubator isolated from the rest of the cell cultures. I found this
helpfull in reducing exposure of others who need to use the incubator in
their work. All of the comments made in the last message are very good.
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html