[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Floor monitors: Model 239-1F
Bicron NE also has floor monitors now. I use the Ludlum, and it has been a
workhorse.
Phil Egidi
ornl/gj
7pe@ornl.gov
At 11:12 AM 9/10/99 -0500, you wrote:
>Mr. Pierson is correct - the Ludlum Model 239-1F can be readily operated in
>dual mode. We run ours with a Ludlum Model 2360 data logger, which
>simultaneously logs alpha, beta, and crosstalk components. It has a 500+
>cm2 active window area. BUT, like most gas flow proportional counters, it
>has a relatively low efficiency for detecting gammas, and no standard
>method for distinguishing gammas from betas. Additionally, the system
>doesn't come equipped with any self-propelled drive system, i.e., someone's
>gotta push it.
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html