[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

AW: Cobalt-60 dose



Doserateconstant for Co-60: 350 µSv.m²/(h.GBq).
Use SI-Units!
Herwig from Salzburg

----------
Von: 	Mark Hart
Gesendet: 	Dienstag, 19. Oktober 1999 02:01
An: 	Multiple recipients of list
Betreff: 	Cobalt-60 dose


I am seeking information and the reference text/article title providing the
answer to the following question.

What is the whole body dose (rem per hour) per gram or per Curie of
unshielded cobalt-60 at a given distance (e.g., anywhere between 1 and 10
meters).


Thank you in advance.

Mark

Mark M. Hart
LLNL/L-125, P.O. Box 808
Livermore, CA  94551
925 423-4770  fax 9762


************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html