[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
re: dosimetry estimates
Rob Kraken suggested that perhaps I could provide some
information to David's question. From Rob's post, it looks like I've
been recently demoted. Hope that's not the case :>
David's question doesn't have a specific answer. The factors are
many. Considerations such as the types of radionuclides used and
the activity of the radionuclide, the tehnician's technique in handling
the radionuclide (orientation of the dosimeter appropriate for the
technique), the type of extremity dosimeter (ring or wrist
dosimeter), the type of element in the ring dosimeter, the algorithm
used (is there specific correction applied for photon energy, beta
energy, fade correction, background subtraction, etc.). If the facility
performs a larger amount of procedures using I-131, the doses
generally tend to be higher. If the typical choice of radionuclides is
Tc-99m, the doses tend to be a bit lower. All of these factors need
to be assessed and each one results in a specific dose estimate
plus the confidence interval in that assessment.
While there is no specific answer, there is a large database of SDE-
ME provided to clients. I can say that generally, typical monthly
dose reports display SDE-ME averaging between 50 to 150
mrem/month. A smaller population range in the mid 100's (200 to
500 mrem/month) and rarely are these dose > 1 rem (although they
do occur). As stated above, the type of radionuclide makes a big
difference in the dose received at the finger or wrist.
The best answer would come from facilities that perform specific
procedures, and, where there is a large number of doses reported
over a long period of time. Hopefully some of those facilities can
provide the information David asked for. I hope that some of my
information is helpful as well.
Rob Kraken stated the following:
> You might check with a good dosimetry vendor like ICN
pharmaceuticlas in Costa Mesa,CA @ 1-714-545-0100 ask for
Sandy Perle-asst technical director. I'm sure he could provide
common doses received from ring dosimeters etc.. RobK
honolulu@u1st.com<
Engelbretson, David A. wrote:
> Would anyone know of some good resources that describe dose
> estimates to hands and fingers from handling nuclear medicine
> radiopharmaceuticals?
> Thank you for your help.
>
> David Engelbretson, MS
> Asst. RSO
> Methodist Hospital
> Houston, Texas
-----------------------
Sandy Perle
Technical Director
ICN Dosimetry Division
3300 Hyland Avenue
Costa Mesa, CA 92626
(800) 548-5100 x2306
(714) 668-3149 Fax
sperle@icnpharm.com
sandyfl@earthlink.net
ICN Dosimetry Website: http://www.dosimetry.com
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html