[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: External dose conversion factors



But the weighting factors used, in FGR 12, are those of ICRP 26, not ICRP 60.

chris a.
alstonc@odrge.odr.georgetown.edu


>The conversion factors for immersion in air, immersion in water, and planar
>sources are found in the US Environmental Protection Agency report by Keith
>Eckerman and Jeffery Ryman
>
>External Exposure to Radionuclides in Air, Water, and Soil, Federal
>Guidance Report No. 12, EPA 402-R-93-081, September 1993.
>******************************
>Joe Alvarez
>Auxier & Associates, Inc.
>9821 Cogdill Rd.
>Suite 1
>Knoxville, TN 37932
>Ph: 865-675-3669
>FAX: 865-675-3577
>email: jalvarez@auxier.com
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html